SV25-F Luftqualitätssensor
Nutzen Sie einen FIPS-validierten All-in-One-Sensor, um neue Erkenntnisse über Ihre Umgebung zu gewinnen.
Maße/Gewicht
L: 170mm / 6.69 in, W: 169.5mm / 6.67 in H: 48mm / 1.88 in, 568 g / 20.04 oz
Kalibrierung
Factory calibrated
Strom
Power Consumption: 4W, Power Input: IEEE 802.3af PoE
Konnektivität
RJ-45 cable connector for Network/PoE connection
LED-Indikator
System power and status indicator
Betriebsbereich
-5°C to +45°C (23°F to 113°F)
Sampling-Frequenz
5s
Gerätespeicher
Up to 365 days
Audiospeicher
Up to 365 days
Cloud-Speicher
Up to 365 days (audio excluded *SV25 only*)
Offline-Modus
Continues sampling and storing data on device
Betriebsbereich
Indoor
Verkaufsländer
USA, Canada, India, UK, EU, Aus, NZ, Rest of World*
Compliance und Sicherheit
For hardware certification information, please visit verkada.com/compliance
Mitgeliefertes Zubehör
Mounting Plate, Installation Kit (with T10 Security Torx Screwdriver, Mounting Screws, Washers, Drywall Anchors & Wing Nuts)
Vorgesehene Installationsstandpunkte
Server room closet (on ceiling or on wall)
Open office area (on ceiling or on wall)
Bathroom/locker room (on ceiling)
Closed rooms (on ceiling or on wall)
Manufacturing floors (on ceiling or on wall)
Hard goods storage facilities (on ceiling or on wall)
Temperatur
Sensor: CMOS
Operating Range: -5 to 45º C (23 to 113° F)
Typical Accuracy: ± 1° C
Units: º C / º F
Luftfeuchtigkeit
Sensor: CMOS
Operating Range: 0 - 95% non-condensing
Typical Accuracy: ± 3% @ 25º C
CO2
Sensor: Photoacoustic
Range: 0 - 40,000 ppm
Typical Accuracy:
400 ppm - 1000 ppm ± 75 ppm
1001 ppm - 2000 ppm ± (40 ppm + 5% of reading)
PM 2.5
Sensor: Laser scattering optical
Sensor Range: 0 - 1000 μg/m3
Typical Accuracy:
0 - 100 μg/m3: ± 25 μg/m3 + 5 % m.v
PM 4
Sensor: Laser scattering optical
Sensor Range: 0 - 1000 μg/m3
Typical Accuracy:
0 - 100 μg/m3: ± 25 μg/m3
100 - 1000 μg/m3: ± 25% m.v.
PM 10
Sensor: Laser scattering optical
Sensor Range: 0 - 1000 μg/m3
Typical Accuracy:
0 - 100 μg/m3: ± 25 μg/m3
100 - 1000 μg/m3: ± 25% m.v.
CO
Sensor: Electrochemical
Range: 0 - 1000 ppm
TVOC-Index
Sensor: MOX
Range: 0 - 500
Luftqualitäts-Index
Sensor: U.S. Air Quality Index, derived from multiple sensors
Range: 0 - 500
Vape-Index
Sensor: Proprietary formula derived from multiple sensors
Range: 0 - 100
Bewegung
Sensor: Passive Infrared Sensor
FoV: 120°
Lärm
Sensor: MEMS Microphone
Range: 20 - 120 dB SPL (A-Weighted)
Typical Accuracy: ± 5 dB
Formaldehyd
Sensor: Electrochemical
Range: 0 - 5000 ppb
Accuracy: ±20 ppb or ±20% m.v., whichever is larger
Licht
Sensor: CMOS
Range: 0 - 7000 lux
Typical Accuracy: ±(6+5% reading) lux
Luftdruck
Sensor: Piezoresistive
Range: 300hPa - 1250 hPa
Typical Accuracy: ±50 Pa
Hitzeindex
Sensor: Formula derived from other sensors
Range: 23 °F to 160 °F
Hitzeindex
Sensor: Formula derived from other sensors
Range: 0-50
Taupunktindex
Sensor: Formula derived from other sensors
Range: 23 °F to 122 °F
Schimmelrisikoindex
Sensor: Formula derived from other sensors
Range: 0-3 Index
RESET® Virenindex
Sensor: Formula derived from other sensors
Range: 0% - 100%
* Es können zusätzliche länderspezifische Anforderungen in Bezug auf Vertrieb und Installation gelten; bitte wenden Sie sich für weitere Informationen an Ihren lokalen Verkada-Händler.
Testen Sie Verkada kostenlos
Das 30-tägige Probe-Abo umfasst eine Kamera sowie Vollzugriff auf die Verwaltungsplattform.