Capteur de qualité de l’air SV25
Un capteur robuste, idéal pour assurer la santé et la sécurité des espaces intérieurs, et plus encore dans les environnements spécialisés.
Dimensions / Poids
L: 170mm / 6.69 in, W: 169.5mm / 6.67 in H: 48mm / 1.88 in, 568 g / 20.04 oz
Étalonnage
Factory calibrated
Alimentation
Power Consumption: 4W, Power Input: IEEE 802.3af PoE
Connectivité
RJ-45 cable connector for Network/PoE connection
Voyant LED
System power and status indicator
Plage de fonctionnement
-5°C to +45°C (23°F to 113°F)
Fréquence d’échantillonnage
5s
Stockage de l’appareil
Up to 365 days
Stockage audio
Up to 365 days
Stockage dans le cloud
Up to 365 days (audio excluded *SV25 only*)
Mode hors ligne
Continues sampling and storing data on device
Zone de fonctionnement
Indoor
Pays de vente
USA, Canada, India, UK, EU, Aus, NZ, Rest of World*
Conformité et sécurité
For hardware certification information, please visit verkada.com/compliance
Accessoires inclus
Mounting Plate, Installation Kit (with T10 Security Torx Screwdriver, Mounting Screws, Washers, Drywall Anchors & Wing Nuts)
Emplacements d’installation prévus
Server room closet (on ceiling or on wall)
Open office area (on ceiling or on wall)
Bathroom/locker room (on ceiling)
Closed rooms (on ceiling or on wall)
Manufacturing floors (on ceiling or on wall)
Hard goods storage facilities (on ceiling or on wall)
Température
Sensor: CMOS
Operating Range: -5 to 45º C (23 to 113° F)
Typical Accuracy: ± 1° C
Units: º C / º F
Humidité
Sensor: CMOS
Operating Range: 0 - 95% non-condensing
Typical Accuracy: ± 3% @ 25º C
CO₂
Sensor: Photoacoustic
Range: 0 - 40,000 ppm
Typical Accuracy:
400 ppm - 1000 ppm ± 75 ppm
1001 ppm - 2000 ppm ± (40 ppm + 5% of reading)
Particules fines PM2,5
Sensor: Laser scattering optical
Sensor Range: 0 - 1000 μg/m3
Typical Accuracy:
0 - 100 μg/m3: ± 25 μg/m3 + 5 % m.v
PM4
Sensor: Laser scattering optical
Sensor Range: 0 - 1000 μg/m3
Typical Accuracy:
0 - 100 μg/m3: ± 25 μg/m3
100 - 1000 μg/m3: ± 25% m.v.
PM10
Sensor: Laser scattering optical
Sensor Range: 0 - 1000 μg/m3
Typical Accuracy:
0 - 100 μg/m3: ± 25 μg/m3
100 - 1000 μg/m3: ± 25% m.v.
CO
Sensor: Electrochemical
Range: 0 - 1000 ppm
Indice COVT
Sensor: MOX
Range: 0 - 500
Indice de la qualité de l’air
Sensor: U.S. Air Quality Index, derived from multiple sensors
Range: 0 - 500
Indice de vapotage
Sensor: Proprietary formula derived from multiple sensors
Range: 0 - 100
Mouvement
Sensor: Passive Infrared Sensor
FoV: 120°
Bruit
Sensor: MEMS Microphone
Range: 20 - 120 dB SPL (A-Weighted)
Typical Accuracy: ± 5 dB
Formaldéhyde
Sensor: Electrochemical
Range: 0 - 5000 ppb
Accuracy: ±20 ppb or ±20% m.v., whichever is larger
Éclairage
Sensor: CMOS
Range: 0 - 7000 lux
Typical Accuracy: ±(6+5% reading) lux
Pression barométrique
Sensor: Piezoresistive
Range: 300hPa - 1250 hPa
Typical Accuracy: ±50 Pa
Indice de chaleur
Sensor: Formula derived from other sensors
Range: 23 °F to 160 °F
Humidex
Sensor: Formula derived from other sensors
Range: 0-50
Indice de point de rosée
Sensor: Formula derived from other sensors
Range: 23 °F to 122 °F
Indice de risque de moisissure
Sensor: Formula derived from other sensors
Range: 0-3 Index
Indice viral RESET®
Sensor: Formula derived from other sensors
Range: 0% - 100%
* Les opérations de vente et d’installation peuvent être soumises à des exigences spécifiques supplémentaires dans certains pays. Pour des informations complémentaires à ce sujet, veuillez vous adresser à votre revendeur Verkada local.
Essayez Verkada gratuitement
L’essai de 30 jours comprend une caméra et l’accès complet à notre plateforme de gestion.